Instrument air & process gas distribution
Custom Instrument Air Header & Distribution Manifold Systems
A central header with independently isolated outlets, engineered around simultaneous demand, pressure drop, valve access, drainage, connection standards and the plant environment.

Flanged inlet · 8 branch valves · terminal valve
Configuration starts with service
Build the header around the operating case
The visible number of valves is only one input. Peak simultaneous demand, minimum user pressure, installed orientation and maintenance access determine whether the arrangement will actually work in service.

Vertical or horizontal headers
Outlet pitch, one- or two-sided branches, inlet position, drain and supports arranged for the installed orientation.

Tube and threaded connections
Compression tube fittings, NPT, BSPP, BSPT, socket-weld or butt-weld ends specified—not simply “half-inch thread.”

Ball, needle or project valve
Valve type, trim, seat, handle, flow direction and locking requirements are matched to the medium and operating procedure.
RFQ engineering inputs
Specify the system—not the photograph
A visually similar header can have a different pressure rating, material compatibility and test requirement. These values must come from the project data.
A header is a pressure-loss chain
Check every restriction to the worst user
A generous header bore cannot correct an undersized supply line, restrictive branch valve or long small-bore tube. Review the complete route and the operating event that creates the highest simultaneous demand.
Plant supply
Available pressure, line size and credible source capacity.
Main isolation
Valve bore, rating, actuation and maintenance clearance.
Header body
Bore, length, branch sequence, slope and supports.
Branch assembly
Valve, fitting, tube size and local resistance.
Worst user
Minimum pressure and response time at the critical device.

Material and construction
Body grade and valve trim are separate decisions
Select the pressure boundary, valves, seals and fittings for both the process medium and external environment.
Design choices that matter in the field
Valve access, drainage and mounting
The assembly must remain operable after tubing, cable trays and nearby equipment are installed. A compact drawing is not useful if technicians cannot turn a handle, connect a tube or reach the drain.
| Design item | What to define | Why it matters |
|---|---|---|
| Outlet spacing | Largest valve envelope, tube bend, wrench access and tag position | Prevents handle interference and supports maintenance |
| Drain / purge | True installed low point, valve type and safe discharge route | Avoids trapped condensate and unsafe discharge |
| Spare outlets | Valved, plugged or capped; contamination protection | Balances expansion capacity against leak paths and cost |
| Mounting | Feet, brackets, bolt pattern, orientation and support loads | Stops connected tubing from becoming structural support |
| Flow direction | Inlet end, branch sequence and valve orientation | Keeps operating labels and valve internals consistent |
| Cleaning | Internal cleanliness, flushing, drying and packaging | Protects instrument service from debris, oil and moisture |
Custom manufacturing route
From process data to inspected assembly
Each stage closes a different source of risk: interface mistakes, inaccessible valves, unsuitable materials, welding distortion, leakage or contamination.
Data review
Medium, pressure, temperature, demand, outlet schedule, connection standards and codes are checked.
Layout confirmation
Header bore, valve arrangement, spacing, drain, supports and overall dimensions are confirmed by drawing.
Fabrication & testing
Material, welds, dimensions, valve operation and project-defined pressure or leak testing are documented.
Clean packaging
Openings are protected, accessories identified and the assembly packed to preserve cleanliness and finish.
Technical resources
Useful before the specification is frozen
Use the engineering guide to build the RFQ, then compare the real product and connection examples.
Frequently asked questions
Before requesting a quotation
How many outlets can an instrument air header have?
The quantity is customized, but it should follow actual users, justified spares, maintenance spacing and the total header length rather than a fixed catalogue count.
Should I use ball valves or needle valves?
Ball valves provide clear quarter-turn isolation and low restriction. Needle valves allow more gradual opening but do not replace a pressure regulator. State the operating purpose, rating, trim and locking requirement.
Where should the drain be located?
At the true low point in the installed orientation, with safe access and a discharge route suitable for the maintenance procedure. A drain drawn at the bottom is not necessarily low after installation.
Can the inlet and outlets use different standards?
Yes. A flanged or welded inlet can be combined with compression, NPT, BSPP, BSPT or weld-end branches. Every interface must be fully designated on the drawing.
Can AODSON provide special alloys and project documentation?
Yes, subject to engineering review and availability. State the grade, traceability, welding, examination, testing, cleaning and document requirements in the RFQ.
Ready for engineering review?
Send the operating data and outlet schedule.
We will turn the process conditions and piping interfaces into a manufacturable header arrangement for confirmation.